Camerafarm Surveillance & Security products from APC
Image |
Product description |
Price |
Buy |
|
APC NetBotz Camera Pod 165 - Network Surveillance Camera - Colour - DC 12 V / PoE :: NBPD0165APC NetBotz Camera Pod 165 - Network Surveillance Camera - Colour - DC 12 V / PoE Product Description | APC NetBotz Camera Pod 165 - network surveillance camera | Device Type | Network surveillance camera - fixed | Dimensions (WxDxH) | 5.6 cm x 3.8 cm x 9.651 cm | Weight | 120 g | Colour | Black | Connectivity Technology | Wired | Camera | Colour | Voltage | DC 12 V / PoE | Features | Alarm function, reset button | Manufacturer Warranty | 2-year warranty | Environmental Parameters (operating) | 0 ?C - 45 ?C; 10 - 90% relative humidity |
|
|
|
|
APC NetBotz Rack Monitor 250 - 2400W, 1U :: NBRK0250Apc NBRK0250 NetBotz Rack Monitor
Features
NetBotz Rack Monitor 250
- Cost-effective and flexible environmental monitoring for all IT
environments, from small edge networks to large data centers
- Includes: Country-specific detachable power cord, Installation guide, Rack
Mounting brackets, Temperature/Humidity Sensor
Overview
Availability |
|
Reduce
Cabling |
Features
wireless sensors to reduce the clutter and expense of
cabling. |
Reboot
equipment remotely |
Saves
dispatching technicians to remote locations. |
Environmental
monitoring |
Prevent
equipment failure from a full range of threatening environmental
conditions. |
Access
monitoring |
Detect
access by unauthorized personnel via door switch. |
Fault
notification |
Real-time
event notification minimizes response times to critical physical
infrastructure situations. Enables IT Administrators to reduce mean time
to repair, improve efficiency, and maximize uptime. |
Manageability |
|
Easy
Integration |
Integrates
with APC racks, NetBotz sensors, and Data Center Expert for easy
deployment, configuration, and management. |
Integrates
with StruxureWare Data Center Expert |
An
IT-ready, scalable access monitoring system that collects, organizes, and
distributes critical alerts, surveillance video |
|
and
key information, providing a unified view of complex physical
infrastructure environments from anywhere on the
network |
Enterprise
management system compatible |
Make
device information available to your preferred enterprise management
system by forwarding SNMP traps (events) across SNMPv1 and SNMPv3 using
the PowerNet MIB |
Marketing
Features |
|
Fault
notification |
Real-time
event notification minimizes response times to critical physical
infrastructure situations. Enables IT Administrators to reduce mean time
to repair, improve efficiency, and maximize uptime. |
Encryption |
Helps
ensure effective access control and integrity for SSL browser and SSH
sessions. |
Browser
Accessible |
View
the user interface with a browser. Provides quick access from anywhere on
a secure network. |
Protection |
|
Password
Security |
User-selectable
password with strong password rules and reset password
mechanism. |
Agility |
|
Flexibility
and adaptability |
Can
be the environmental monitoring solution, or the rack access control
solution, or both. |
Adjustable
threshold |
Customize
threshold definitions (multiple thresholds per sensor, scheduling,
severity levels) to your requirements. |
Slim
form factor |
Can
be mounted in a rack alongside other IT gear, or zero –U mounted in the
back |
Total
Cost of Ownership |
|
Browser
Accessible |
View
the user interface with a browser. Provides quick access from anywhere on
a secure network. |
Specifications
Input |
|
Number
of Power Cords |
1 |
Input
Power |
2400.0Watts |
|
Physical |
Maximum
Height |
1.72inches
(44mm, 4.4CM) |
Maximum
Width |
17.0inches
(432mm, 43.2CM) |
Maximum
Depth |
2.33inches
(59mm, 5.9CM) |
Rack
Height |
1U |
Net
Weight |
2.8lbs.
(1.27KG) |
Shipping
weight |
6.5lbs.
(2.95KG) |
Shipping
Height |
2.6inches
(66mm, 6.6CM) |
Shipping
Width |
18.0inches
(457mm, 45.7CM) |
Shipping
Depth |
8.9inches
(226mm, 22.6CM) |
Environmental |
|
Operating
Temperature |
32
- 113 °F (0 - 45 °C) |
Operating
Relative Humidity |
0
- 95 % |
Operating
Elevation |
0-10000ft
(0-3000meters) |
Storage
Temperature |
-15
- 65 °C |
Storage
Relative Humidity |
0
- 95 % |
Storage
Elevation |
0-50000ft
(0-15000meters) |
Conformance |
|
Standard
warranty |
2
years repair or replace |
|
Sustainable
Offer Status |
RoHS |
Compliant |
REACH |
REACH:
Contains SVHCs |
Battery
Directive |
Compliant |
General |
|
Type
of Camera Pods Supported |
Rack
Sensor Pod 150 |
Type
of External Sensors Supported |
Door
Contact, Dry Contact, Humidity, Smoke, Fluid Spot Leak, Temperature,
Vibration |
Number
of Additional Camera Pods |
6 |
Number
of Additional Sensor Pods |
6 |
Sensor
Humidity Range |
±3%
RH from 11% to 89% RH % |
External
Sensor Ports |
0
Integrated, 0 Networked, 0 USB |
Sensor
Temperature Range |
15°C
to 50°C (32°F to 122°F) +/- 1°C (1.8°F)
°F |
|
|
|
|
APC NetBotz Room Monitor Camera 455 - Without PoE Inj :: NBWL0455
2-Way audio
Supports remote service capability through speaker and microphone inputs. Advanced Software Pack #1 required to enable functionality.
NetBotz 400 Features & Benefits
Access monitoring
Detect access by unauthorized personnel via door switch.
Environmental Monitoring
Prevent equipment failure from a full range of threatening environmental conditions.
Surveillance
Detect and record motion, allowing a visual record to be paired with an access or environmental alert, which speeds root cause analysis.
Fault notification
Real-time event notification minimizes response times to critical physical infrastructure situations. Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime.
Adjustable threshold
Customize threshold definitions (multiple thresholds per sensor, scheduling, severity levels) to your requirements.
Customized escalation policies
Alerts are managed according to your escalation policies and received in multiple formats.
Browser Accessible
View the user interface with a browser. Provides quick access from anywhere on a secure network.
Event-driven video storage
Video storage prompted by motion or alert.
Password Security
User-selectable password protection prevents unauthorized access.
Integrates with InfraStruXure Central
An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Advanced View client application
Robust appliance interface provides historic alerts, graphs, and configuration.
Enterprise management system compatible
Manage your APC devices from a single system by forwarding SNMP traps (events) to your preferred enterprise management system.
Alerts View
Easily review and correlate alerts. Provide context to alerts by attaching video clips, graphs, and maps.
Number of Additional Sensor Pods
2
Communications & Management
Protocols
DHCP,DNS,HTTP,HTTPS,SMTP,SOCKS,TCP/IP
Network Interface Connections
RJ-45 10/100 Base-T
Operating Environment
0 - 45C
Storage Temperature
-15 - 65C
Operating Relative Humidity
0%
Storage Relative Humidity
0%
Operating Elevation
0-3000meters
Storage Elevation
0-15000meters
Regulatory Approvals
AS/NZS 3548 (C-Tick) Class A,CE,FCC Part 15 Class A,ICES-003,Low Voltage Directive 2006/95/EC,VCCI Class A
Standard Warranty
2 years repair or replace
|
|
|
|
APC NetBotz Room Sensor Pod 155 :: NBPD0155 NBPD0155 Features A-Link communication port Deployment flexibility allows sensor pods to be up to 1000 meters from a compatible NetBotz appliance. Wall mountable Ideal for Network Closets and Server Rooms.
NetBotz Sensors Features & Benefits Availability
Low profile sensors Small sensors allow for placement flexibility.
Optional sensors Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc.
Unique identifiers Customize each sensor with a differentiating name and location.
Operating Environment
0 - 45C
Storage Temperature
-15 - 65C
Operating Relative Humidity
0%
Storage Relative Humidity
0%
Operating Elevation
0-3000meters
Storage Elevation
0-15000meters
Regulatory Approvals
AS/NZS 3548 (C-Tick) Class A,cUL Listed,CE,FCC Part 15 Class A,ICES-003,Low Voltage Directive 2006/95/EC,PSE,UL Listed,VCCI Class A,VDE
Standard Warranty
2 years repair or replace
|
|
|
|
APC NetBotz Rack Sensor Pod 150 :: NBPD0150 NBPD0150 Features A-Link communication port Deployment flexibility allows sensor pods to be up to 1000 meters from a compatible NetBotz appliance. Rack mountable Includes horizontal, vertical and toolless-mount capabilities.
NetBotz Sensors Features & Benefits Availability
Low profile sensors Small sensors allow for placement flexibility.
Optional sensors Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc.
Unique identifiers Customize each sensor with a differentiating name and location.
Operating Environment
0 - 45C
Storage Temperature
-15 - 65C
Operating Relative Humidity
0%
Storage Relative Humidity
0%
Operating Elevation
0-3000meters
Storage Elevation
0-15000meters
Regulatory Approvals
AS/NZS 3548 (C-Tick) Class A,CE,FCC Part 15 Class A,GOST,ICES-003,NOM,VCCI Class A
Standard Warranty
2 years repair or replace
|
|
|
|
APC NetBotz Smoke Sensor - 10ft. :: NBES0307 NBES0307 Features RJ-45 sensor connection type Automatically detected by compatible NetBotz appliances and easily extended with standard CAT5/6 cable to 100 feet.
NetBotz Sensors Features & Benefits Availability Low profile sensors Small sensors allow for placement flexibility.
Optional sensors Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc.
Unique identifiers Customize each sensor with a differentiating name and location.
Operating Environment
0 - 45C
Storage Temperature
-15 - 65C
Operating Relative Humidity
0%
Storage Relative Humidity
0%
Operating Elevation
0-3000meters
Storage Elevation
0-15000meters
Standard Warranty
2 years repair or replace
|
|
|
|
APC NBES0303 Netbotz DSSs 2 for Rack - 12ft. :: NBES0303 NBES0303 Features RJ-45 sensor connection type Automatically detected by compatible NetBotz appliances and easily extended with standard CAT5/6 cable to 100 feet.
NetBotz Sensors Features & Benefits Availability Low profile sensors Small sensors allow for placement flexibility.
Optional sensors Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc. Agility
Unique identifiers Customize each sensor with a differentiating name and location.
Operating Environment
0 - 45C
Storage Temperature
-15 - 65C
Operating Relative Humidity
0%
Storage Relative Humidity
0%
Operating Elevation
0-3000meters
Storage Elevation
0-15000meters
Standard Warranty
2 years repair or replace
|
|
|
|
APC Netbotz DSS Rooms/3rd Party Racks - 50ft. :: NBES0302
Operating Environment
0 - 45C
Storage Temperature
-15 - 65C
Operating Relative Humidity
0%
Storage Relative Humidity
0%
Operating Elevation
0-3000meters
Storage Elevation
0-15000meters
Standard Warranty
2 years repair or replace
|
|
|
|